Three-Stage Rotary Valve Plunger Pump adopts a three-station independent flow path design, integrating suction, discharge, and cleaning in one body. With ceramic valve and plunger as core components, it features ultra-high precision, zero cross-contamination, high efficiency, and strong chemical resistance. It is widely used in biopharmaceutical, CGT, semiconductor, food, and cosmetic industries for multi-fluid precise dosing.

Pump Rod Diameter / mm: 10 / 20 / 28 / 35 / 50

Min. Filling Volume / ml: 0.5 / 2 / 5 / 10 / 20

Max. Filling Volume / ml: 3 / 10 / 25 / 50 / 100

Filling Accuracy :±1% – ±0.5% (for fluid ≤20000cp, no solid particles)

  • Product Details
  • Technical Specifications

Core Structure & Working Principle

Three-Stage Rotary Valve (Core Control Unit)

  • Material: Zirconia / SiC ceramic, hardness ≥1500 HV, resistant to pH 0–14 & organic solvents.
  • Three independent flow channels: Synchronous suction + discharge + cleaning (3-station seamless switching).
  • Zero cross-contamination: Channel spacing ≥2 mm, suitable for toxic / high-activity media.
  • Drive: Stepper / servo motor, angle positioning ≤0.1°, switching time ≤50 ms (up to 300 cycles/min).

Ceramic Plunger Unit (Precision Metering Module)

  • Material: Si₃N₄ / Al₂O₃ with DLC coating, friction coefficient ≤0.07.
  • Metering accuracy: ±0.2% CV, repeat positioning accuracy ±1 μm.

Applications of Valve Plunger Pump

Biopharmaceutical & CGT (Cell & Gene Therapy)

  • Viral vector & medium processing: Independent channels avoid inactivation.
  • CIP/SIP capable: 135°C steam, 0.1 MPa.
  • ADC production: Toxic payload & buffer switching, leakage ≤1×10⁻⁶ mL/min.

Semiconductor Manufacturing

  • Photoresist & developer supply: Resists acetone, PGMEA.
  • Flow fluctuation ≤0.3% for nano-coating.
  • Multi-component electroplating dosing: Ratio error ≤0.5%.

Food & Cosmetics

  • Multi-flavor beverage filling: 3 formulas seamless switching, residue ≤0.01 mL.
  • Microcapsule packaging: Core /wall/cross-linking agent synchronous pumping.
ItemThree-Stage Rotary Valve PumpTraditional Single Valve Pump
Multi-Task EfficiencySuction / discharge / cleaning at the same time (efficiency +200%)Single-station sequential operation
Fluid CompatibilitySupports 3 incompatible fluids alternatelySingle fluid only
Dead Volume≤0.5 μL (self-emptying)≥5 μL (residue causes cross-contamination)
Power Consumption15 W (low inertia)30–50 W (frequent start-stop loss)